[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] RE: some numbering clarificationsJulo, > Pierre, > > - Command numbering. Initiator sets InitCmdRN to 0. All the > others can also > be 0. > is there any drawback? Perhaps Matt, you should make a comment. On a single connection without the command window, an option that Julo has implemented by removing requirement for CmdRN on a single connection, there would be no means to prevent communication buffers from closing. Should the target wish to keep communications open for required data, this is no longer possible. The target could not keep buffers lean and thus not assure latency. The application driver could have paced itself with a command window to prevent full buffers creating head of queue blocking. Doug
Home Last updated: Tue Sep 04 01:06:36 2001 6315 messages in chronological order |