[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] ISCSI: Flags in header indicating that digest is presentJulian, At some point, we had bits in the BHS that indicated whether Header Digest and/or Data Digest is present. They now have disappeared, perhaps when we removed the WN-based PDUs for Draft-6. Now, how do we know from the PDU itself whether it is present or not? If not, is the intention that we maintain the current state of the digest negotiation and apply it to all PDUs? From Draft 5: ---------------- 2.2.1 What's Next (WN) This is an encoded field that indicates what the next segment is. bit 7 - 1 Next is another header segment. bit 6-4 Next header type code 0 Extended CDB 1 Bi-directional read-data transfer header 2 Long Data Header 3,4,5,6,7 Reserved bit 3-0 Reserved bit 7 - 0 Next is a data segment or no additional segment (empty data segment) bit 6 Header Digest Present (1) or Not (0) bit 5 Data Digest Present (1) or Not (0) bit 4-0 Reserved ------------------ Thanks, Venkat Rangan Rhapsody Networks Inc. http://www.rhapsodynetworks.com