[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] Re: iSCSI: Data in Response PDUsThat is absolutely correct. No data besides response/sense are supposed to arrive in the response PDU. Julo John Vrabel <JVrabel@advaoptical.com> on 05-07-2001 10:43:22 Please respond to John Vrabel <JVrabel@advaoptical.com> To: Julian Satran/Haifa/IBM@IBMIL cc: Subject: Re: iSCSI: Data in Response PDUs I'm sorry I asked the question very badly - I mistakenly said Status PDU instead of Response PDU. Both the Intel version-03 code and the Swat version-03 send Read Data as part of Response PDUs, which I believe is wrong. My understanding is that all Read Data MUST be sent in Data-In PDUs. Only Sense Data can be included in a Response PDU. Is this correct.? John Vrabel