[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] RE: how much "Desired Data Transfer Length" in R2THi sastry, What you specified is during negotiation, I am referring to after the negotiation, when DataPDULength has been decided. But Later when R2T's needs to be send from target, examples have been given in the draft that depicts one R2T is sent from the target and it receives 2 Data PDU's. It means that target specified more size than DataPDULength in the R2T, on what basis did the target decide that. Thanks, nitin -----Original Message----- From: Subrahmanya Sastry K.V [mailto:skotra@npd.hcltech.com] Sent: Monday, October 22, 2001 3:32 AM To: Nitin Dhingra Cc: ips@ece.cmu.edu Subject: Re: how much "Desired Data Transfer Length" in R2T Nitin, I think the "Desired Data Tranfer Length" field of R2T PDU should be equal to the DataPDULength value that the initiator has sent to the target during text parameter negotiation. Since the DataPDULength can be different in the two directions, the initiator sends this value to the target as DataPDULength=<value>. So the initiator only sends/receives a PDU having length less than or equal to the negotiated DataPDULength (non-zero). Any comments are welcome.. Sastry Nitin Dhingra wrote: > How is the target going to decide how much "desired data transfer length" he > has > to fill apart from the negotiated "DataPDULength". > > Thanks in advance, > nitin
Home Last updated: Mon Oct 22 10:17:31 2001 7319 messages in chronological order |