|
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] RE: iSCSI: Representing iSCSI devices on FC fabricsCorrection - the company_id is 24 bits, not 20 bits. EUI-64 = (MSB) { 24-bit company_id, 40-bit vendor specified } (LSB) FC WWN = (MSB) { 4-bit NAA field, 24-bit company_id, 36-bit vendor specified } (LSB) (for the IEEE Registered NAA type) > -----Original Message----- > From: Elliott, Robert > Sent: Friday, November 16, 2001 9:33 AM > To: ips@ece.cmu.edu > Subject: RE: iSCSI: Representing iSCSI devices on FC fabrics > > > Beware than a FC WWN is not the same as an EUI-64. They're both based > on the IEEE OUI/company_id, but the FC WWN uses the 4 most significant > bits for a "Name Address Authority" field and has 4 fewer > bits available > in the vendor specified portion. > > EUI-64 = (MSB) { 20-bit company_id, > 44-bit vendor specified } (LSB) > > FC WWN = (MSB) { 4-bit NAA field, > 20-bit company_id, > 40-bit vendor specified } (LSB) > (for the IEEE Registered NAA type) > > --- > Rob Elliott, Compaq Server Storage > Robert.Elliott@compaq.com
Home Last updated: Mon Nov 19 09:17:42 2001 7850 messages in chronological order |