    Re: iSCSI:Time2Retain



    
    John,
    
    The intent of the parametrs is the same and we will fix the wording to say
    it.
    
    Thanks,
    Julo
    
    
                                                                                                         
                        John                                                                             
                        Hufferd@IBMUS        To:     Julian Satran/Haifa/IBM@IBMIL@IBMDE                 
                                             cc:     ips@ece.cmu.edu                                     
                        30-12-01 05:54       From:   John Hufferd/San Jose/IBM@IBMUS                     
                                             Subject:     iSCSI:Time2Retain                              
                                                                                                         
                                                                                                         
                                                                                                         
    
    
    
    Julian,
    I am wondering if we have a minor discrepancy between the Asynchronous
    Message PDU and the Logout Response PDU.
    
    The Asynchronous Message Parameter3 is the "Time2Retain" variable, and it
    is the maximum time to reconnect after the initial wait (Parameter2) which
    is the "Time2Wait".
    
    The Logout Response PDU has both the "Time2Wait" and the "Time2Retain" but
    the "Time2Retain" is defined as the "maximum time that the target waits for
    a connection reinstatement Login after which the connection state is
    discarded", and that definition makes no reference to the "Time2Wait".
    
    Since Both "Time2Wait" and "Time2Retain" are specified in both PDUs, the
    question is: did we intend in the Logout Response PDU to have no relation
    between the two values, and did we intend the two Commands to have
    different interpretations of the "Time2Retain" variable?
    
    .
    .
    .
    John L. Hufferd
    Senior Technical Staff Member (STSM)
    IBM/SSG San Jose Ca
    Main Office (408) 256-0403, Tie: 276-0403,  eFax: (408) 904-4688
    Home Office (408) 997-6136, Cell: (408) 499-9702
    Internet address: hufferd@us.ibm.com
    
    
    
    