[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] RE: sector alignment for DataOut PDUs?>>>>> "Rod" == Rod Harrison <rod.harrison@windriver.com> writes: Rod> I have no objection in principle to this but I have a concern Rod> over non-media access commands. Things like mode select Rod> payloads, i.e. defect lists etc are not necessarily 512 byte Rod> multiples. The wording would need to allow "odd" sizes when the Rod> SCSI transfer length is not a 512 byte multiple. Are those DataOut or DataIn? The target can arrange inbound PDU sizes to be whatever multiple is helpful if it wants to, that isn't the case I was talking about. In any case, if there are cases where the total transfer length for data out isn't a multiple of 512, then the rule would have to allow the last transfer to have an odd length. The earlier transfers could still be constrained if the constraint is enabled. paul