[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] RE: [iSCSI:] Logout request -- reason? CorrectionLuben, I don't see where you got that impression. The BHS layout shows bytes 1 through 3 as opcode specific fields. The kinds of opcode specific fields will be different depending upon opcode. Pat -----Original Message----- From: Luben Tuikov [mailto:luben@splentec.com] Sent: Monday, May 27, 2002 6:49 AM To: iSCSI; Julian Satran Subject: [iSCSI:] Logout request -- reason? Correction Let me correct this: I was under the impression that byte 1 in BHS is a flags byte -- i.e. bit values. I now see that the reason code is moved exactly there, in the Logout request PDU. Could anyone please explain the logic behind this? At the same time byte 2 and 3 are reserved to 0. Why don't we: 1) Move the reason code to byte 2. This will make it _consistent_ with the response byte in Logout Response. 2) Make the value start at 0x80, as to hide the ugliness of F = 1, and the fact that we are trying to fit a numerical value (!) and a bit value (!) in the same octet. Comments? -- Luben