[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] iSCSI: Numeric RangesI am unclear on how to select a value when given a Numeric Range. O-> MaxConnections=2~5 As the Responder I want 3. The "selection rule" for MaxConnections says "the lower of the 2 values". So one value is 2~5 the other is 3. Thus the min of those is 2....?.? If this is the case, I'm not seeing the necessity or added value of "numeric ranges". The initiator could just send the min value in the possible range (when the key's selection rule is min()). Thanks. Mike Donohoe